250A 4 Pole Electronic LCD Residual Current MCCB
  • 250A 4 Pole Electronic LCD Residual Current MCCB250A 4 Pole Electronic LCD Residual Current MCCB

250A 4 Pole Electronic LCD Residual Current MCCB

Dongfa Intelligent supplies 250A 4 pole electronic LCD residual current MCCBs for panels needing ground fault and selectivity control. Rated 250A with 65/65kA at 400V, 10kA/1s Icw, and an LCD screen, it fits 4-wire bays. Request a quote for pricing and specs.
    250A 4 Pole Electronic LCD Residual Current MCCB

    Where Four-Wire Ground Fault Protection Meets Front-Panel LCD Readouts

    Four-wire distribution circuits serving workshops, outdoor equipment, wet process areas, or sensitive commercial loads face both phase-to-earth insulation leakage and short-circuit fault stress. When protection settings are buried or unclear during commissioning, technicians spend extra time checking parameters and verifying coordination across panels.

    Dongfa Intelligent supplies this 250A 4 pole electronic LCD residual current MCCB to combine electronic residual current protection, Cat B selectivity, and front LCD readouts in a four-wire molded case unit. Built to IEC 60947-2 and GB/T 14048.2 standards, it gives switchgear builders a practical way to set residual trip thresholds and inspect status on the front face.

    Front Face Markings, LCD Display, and Keypad Controls

    Examining the front face of this 250A unit shows how protection parameters, indicators, and adjustment controls are laid out:

    Left Rating Block and Red TRIP Button: The left panel marks In 250A, IR 100-250A, Ue AC 400V, Icu/Ics 65/65kA, IΔN 50MA, 100MA, 200MA, 300MA, 400MA, 500MA, 1000MA, DELAY TIME 0.2-2S, ICW 10KA/1S, CAT B, and IΔT(S) 0.06/0.2/0.5/1.0S, alongside a red TRIP button on the lower left.

    Right ELCB Block, LCD Screen, and Neutral N Pole: The upper right displays ELCB, UI AC 1000V, UIMP 8KV, 50HZ, GB/T 14048.2, and IEC 60947-2, with the fourth neutral pole clearly marked N beside an LCD window and three status indicators for power, alarm, and communication.

    Lower Keypad and Multi-Pin Terminal Strip: Along the lower front strip sit four pushbuttons (confirm/modify, up, down, and return/shift) next to a green multi-pin terminal block marked with communication and control terminals (A, B, COM, DI), with LINE at the top and LOAD at the bottom.

    Parameter Nameplate / Spec Value Practical Engineering Meaning
    Rated Current & Range (I_n / I_R) 250A (IR 100-250A; series spans 40A–800A frames) Suits 250A four-wire circuits with adjustable pickup current range
    Poles & Neutral Marking 4P with N pole marked Switches three phases and neutral across four-wire distribution lines
    Rated Operational Voltage (U_e) AC 400V Matches standard three-phase four-wire 400V AC power systems
    Breaking Capacity (I_{cu}/I_{cs}) 65/65kA at AC 400V Full Ics = 100% Icu rating supports continued service after fault clearing
    Short-Time Withstand (I_{cw}) 10KA/1S Supports Cat B short-time delay coordination up to 10kA for 1 second
    Residual Current & Delay Time IΔN 50–1000mA steps; delay 0.2–2S / 0.06/0.2/0.5/1.0S Allows tuning earth leakage sensitivity and delay time to system needs
    Insulation / Impulse (U_i / U_{imp}) AC 1000V / 8KV Sets dielectric insulation reference and impulse withstand level
    Display & Terminal Interface LCD screen + 3 status LEDs + 4 buttons + terminal strip Provides on-face parameter viewing, button navigation, and external wiring

    Panel Wiring Checks, Series Options, and Manufacturing Quality

    When installing this 250A 4 pole electronic LCD residual current MCCB into a switchboard, route phase and neutral conductors cleanly through their respective poles so normal balanced load currents do not trigger false leakage readings, and check door window alignment so the LCD readout and four front buttons remain accessible.

    Across the electronic LCD residual current MCCB series, 4P frame sizes cover 160A through 800A with M and H breaking codes, AC type electronic residual sensing, and Class B selectivity. Drawing on 14 years of low- and medium-voltage electrical manufacturing experience in Yueqing, Dongfa Intelligent tests every batch under ISO 9001 controls and IEC 60947-2 / GB/T 14048.2 standards—verifying mechanical switching, insulation and dielectric strength, residual trip response, and LCD/indicator operation before shipping, with sample orders and custom OEM silk-screen markings available.

    Technical Specifications

    Molded Case Circuit Breaker (with Residual Current Protection) STM6ELY-160 STM6ELY-250 STM6ELY-400 STM6ELY-630 STM6ELY-800
    Breaking Capacity Code M H M H M H M H M H
    Frame Rated Current In (A) 40–100A; 50–125A; 63–160A 50–125A; 100–250A 160–400A 252–630A 630A (252–630A); 800A (320–800A)
    Poles 4P 4P 4P 4P 4P
    Rated Working Voltage Ue, AC AC400V AC400V AC400V AC400V AC400V
    Rated Insulation Voltage Ui (V) 1000V 1000V 1000V 1000V 1000V
    Rated Impulse Withstand Voltage Uimp (kV) 8kV 8kV 8kV 8kV 8kV
    Ics @ AC400V (kA) 25kA 50kA 25kA 50kA 35kA 50kA 35kA 50kA 50kA 65kA
    Icu @ AC400V (kA) 35kA 65kA 35kA 65kA 50kA 70kA 50kA 70kA 50kA 85kA
    Rated Short-Time Withstand Current Icw 10kA/1s 10kA/1s 10kA/1s 10kA/1s 10kA/1s 10kA/1s 10kA/1s 10kA/1s 20kA/1s 20kA/1s
    Rated Residual Operating Current IΔn (mA) 50, 100, 200, 300, 500, 800, 1000 mA stepped adjustment / AC type 50, 100, 200, 300, 500, 800, 1000 mA stepped adjustment / AC type 50, 100, 200, 300, 500, 800, 1000 mA adjustable / AC type 50, 100, 200, 300, 500, 800, 1000 mA adjustable / AC type 50, 100, 200, 300, 500, 800, 1000 mA adjustable / AC type
    IΔm 25% Icu 25% Icu 25% Icu 25% Icu 25% Icu
    Selectivity Category Class B Class B Class B Class B Class B
    Overcurrent Release Type Electronic Electronic Electronic Electronic Electronic
    Residual Current Release Type Electronic Electronic Electronic Electronic Electronic
    Poles (Dimensions) 4P 4P 4P 4P 4P
    Width W (mm) 120 140 184 184 280
    Length L (mm) 150 165 257 257 275.5
    Height – Cover (mm) 82 88 103 103 103
    Height – Handle (mm) 108 116 152 152 152

    Buyer Feedback and Common Questions

    "We used Dongfa Intelligent's 250A 4 pole electronic LCD residual current MCCBs on a commercial distribution board requiring ground-fault selectivity. Having 65/65kA breaking at 400V, clear N marking, and a front LCD display with keypad buttons made panel setup straightforward after testing a sample first."

    — Nabil H., Electrical Project Lead at a Gulf Region Switchgear Builder

    How are residual current and delay time settings handled on this 250A breaker?

    The left faceplate lists residual operating current steps (IΔN from 50mA to 1000mA) and delay time options (0.2–2S and 0.06/0.2/0.5/1.0S), while the front LCD screen and four pushbuttons support viewing and setting parameters on the unit.

    Can we order 1 unit at 250A first for sample and panel testing?

    Yes. Sample and small-batch orders are available so your team can check the 4P dimensions, LCD display, and terminal layout before ordering in bulk.

    Can you print our brand name or custom markings on the faceplate?