160A 3 Pole Thermal Magnetic Molded Case Circuit Breaker
  • 160A 3 Pole Thermal Magnetic Molded Case Circuit Breaker160A 3 Pole Thermal Magnetic Molded Case Circuit Breaker

160A 3 Pole Thermal Magnetic Molded Case Circuit Breaker

Dongfa Intelligent supplies 160A 3 pole thermal magnetic molded case circuit breakers for panel builders and wholesale buyers handling low-voltage overload and short-circuit protection. Rated 85kA breaking capacity at 400V with clear trip indication, it supports OEM branding. Request a quote for bulk pricing and catalog specs.

    In low-voltage main distribution boards, motor control centers, and commercial switchgear cabinets, feeder breakers need to handle motor starting surges without nuisance tripping while still interrupting overloads and heavy phase-to-phase faults quickly. Dongfa Intelligent supplies this 160A 3 pole thermal magnetic molded case circuit breaker built to IEC 60947-2 and GB 14048.2 standards. Designed for 400V and 690V AC networks, it gives panel builders a dependable protection unit with OEM marking options for bulk distribution.

    160A 3 Pole Thermal Magnetic Molded Case Circuit Breaker

    How Thermal-Magnetic Dual Protection Solves Panel Issues

    Engineers and panel assemblers frequently run into two headaches on low-voltage feeders: nuisance trips when motors start up, or slow fault clearing during high-current short circuits. Pairing a thermal element with a magnetic trip element handles both operating conditions:

    Thermal Overload Trip: When continuous current exceeds the 160A rating over time, a bimetallic strip heats up and bends to release the trip bar. Higher overloads shorten trip time, letting brief motor start-up currents pass while protecting cable insulation from prolonged thermal aging.

    Magnetic Short-Circuit Trip: When a severe short circuit strikes downstream, fault current energizes the magnetic coil to pull the release mechanism almost instantaneously, driving the arc into the quenching chamber to clear the fault before busbars or conductors suffer heavy damage.

    Front TRIP Test Button: Right on the front face below the operating handle, a red TRIP button lets technicians manually verify trip linkage release during panel commissioning without injecting high test current.

    Rated Specifications From the Nameplate

    When checking technical schedules for low-voltage assemblies, the nameplate ratings define the breaker's switching and insulation limits:

    Parameter Rated Specification Practical Engineering Meaning
    Poles & Rated Current (I_n) 3 Pole (3P) / 160A Fits three-phase low-voltage feeder and main distribution circuits
    Rated Operational Voltage (U_e) AC 240V / 400V / 690V Covers standard 400V commercial/industrial grids and 690V heavy circuits
    Ultimate Breaking Capacity (I_{cu}) 100kA (240V) / 85kA (400V) / 20kA (690V) Maximum prospective fault current the breaker is rated to clear
    Service Breaking Capacity (I_{cs}) 80kA (240V) / 50kA (400V) / 10kA (690V) Indicates fault interruption capability while remaining fit for continued service
    Rated Insulation Voltage (U_i) AC 690V Sets the voltage reference for internal phase and earth insulation clearances
    Rated Impulse Withstand (U_{imp}) 6kV Withstands transient switching and lightning-induced voltage spikes
    Utilization Category & Temp Cat A / 50Hz / +40°C Suited to general-purpose non-selective protection with ratings calibrated at +40°C
    Standards & Marks IEC 60947-2 / GB 14048.2 / CCC Aligns with international low-voltage switchgear testing standards

    Selection and Installation Notes to Avoid Field Mistakes

    Follow LINE and LOAD Markings: The molded housing clearly marks LINE at the top supply side and LOAD at the bottom load side. Wire the supply feed to the LINE terminals as intended so arc extinguishing and trip mechanics perform properly during high-fault interruption.

    Fit Phase Barriers on Heavy Terminations: When terminating wide copper busbars or heavy cable lugs, install insulating phase barriers between terminals to keep creepage and clearance paths safe inside crowded enclosures.

    Account for Ambient Enclosure Heat: Thermal trip calibration references a +40°C ambient baseline. If you mount the breaker inside a sun-exposed outdoor box or poorly ventilated cabinet exceeding +40°C, review temperature derating or cabinet ventilation early in panel design.

    Factory Checks, OEM Customization, and Dispatch

    Dongfa Intelligent manufactures this 160A 3 pole thermal magnetic molded case circuit breaker with factory routine checks covering thermal trip timing, magnetic trip response, dielectric withstand, and mechanical switching cycles before shipping.

    OEM Branding & Neutral Option: We support neutral faceplates or custom customer silk-screen markings (brand logo, part codes, and ratings) for regional distributors and OEM panel builders.

    Sample & Bulk Packaging: Buyers can request sample units for local testing before placing volume orders, with each breaker packed in an individual box and outer cartons suited to sea freight.

    Technical Specifications

    Thermal-Magnetic Molded Case Circuit Breaker 125 160 250 400 630 800 1250 2000
    Frame Rated Current In (A) 10A-125A 16A-160A 100A-250A 250A-400A 500A-630A 800A-800A 800A-1250A 1000A-2000A
    Poles 1P,2P,3P,4P 2P,3P,4P 3P,4P 3P,4P
    Rated Insulation Voltage Ui (V) 1000V
    Rated Impulse Withstand Voltage Uimp (kV) 8Kv
    Rated Operational Voltage Ue (V), AC 230V;400V;690V
    Breaking Capacity Code C S M H C S M H C S M H S M H M H M H S M H M H
    Rated Service Short-Circuit Breaking Capacity Ics (kA) AC230V 5 15 35 50 7 10 25 35 20 25 40 50 25 40 50 40 50 65 70 40 65 70 – –
    AC400V 5 13 18 50 10 13 18 35(2P)50(3P4P) 10 15 35 50 15 35 65 35 65 50 65 35 50 65 50 85
    AC690V 3 3 5 8 2 3 5 10 3 4 10 15 4 10 12 10 12 15 20 10 15 20 20 20
    Rated Ultimate Short-Circuit Breaking Capacity Icu (kA) AC230V 8 30 36(2P)50(3P4P) 50 10 20 30 50 30 50 65 70 50 65 70 30 50 80 85 65 80 85 – –
    AC400V 8 25 36 50 15 25 36 50 15 30 50 65 30 50 65 50 65 65 85 50 65 85 50 100
    AC690V 5 6 10 15 8 6 10 15 5 8 15 20 8 20 25 10 20 25 35 20 25 35 20 25
    Mechanical Endurance (Operations) 8500 8500 7000 4000 4000 2500 2500 2500
    Electrical Endurance (Operations) 1500 1500 1000 1000 1000 500 500 500
    Overall Dimensions Poles 1P 2P 3P 4P 2P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P
    Width 25 50 75 100 60 90 120 105 140 140 184 140 184 210 280 210 280 210 280
    Length 130 155 165 257 257 275.5 257.5 340
    Height (S/H) 68 68/82 68/88 103 103 103 103 141
    Height (S/H) 94.5 94/108 96/116 152 152 152 152 244

    Frequently Asked Questions

    Are you a factory or trading company, and can we order samples first?

    We are a direct manufacturer with 14 years of low-voltage and medium-voltage electrical manufacturing experience. Sample orders are available so your team can test fitment and performance before committing to bulk quantities.

    Can this 160A breaker take shunt trip, undervoltage, or auxiliary contacts?

    Yes. Internal accessory slots support common add-ons such as auxiliary contacts, shunt trips, undervoltage releases, or rotary handles depending on your control circuit requirements.

    What is the typical lead time for bulk and OEM orders?

    Standard 160A configurations typically ship in 5–7 working days when stock components are ready, while custom OEM printing or accessory assemblies generally take 10–15 working days.