160A 3 Pole Thermal Magnetic Molded Case Circuit Breaker
Dongfa Intelligent supplies 160A 3 pole thermal magnetic molded case circuit breakers for panel builders and wholesale buyers handling low-voltage overload and short-circuit protection. Rated 85kA breaking capacity at 400V with clear trip indication, it supports OEM branding. Request a quote for bulk pricing and catalog specs.
In low-voltage main distribution boards, motor control centers, and commercial switchgear cabinets, feeder breakers need to handle motor starting surges without nuisance tripping while still interrupting overloads and heavy phase-to-phase faults quickly. Dongfa Intelligent supplies this 160A 3 pole thermal magnetic molded case circuit breaker built to IEC 60947-2 and GB 14048.2 standards. Designed for 400V and 690V AC networks, it gives panel builders a dependable protection unit with OEM marking options for bulk distribution.
How Thermal-Magnetic Dual Protection Solves Panel Issues
Engineers and panel assemblers frequently run into two headaches on low-voltage feeders: nuisance trips when motors start up, or slow fault clearing during high-current short circuits. Pairing a thermal element with a magnetic trip element handles both operating conditions:
Thermal Overload Trip: When continuous current exceeds the 160A rating over time, a bimetallic strip heats up and bends to release the trip bar. Higher overloads shorten trip time, letting brief motor start-up currents pass while protecting cable insulation from prolonged thermal aging.
Magnetic Short-Circuit Trip: When a severe short circuit strikes downstream, fault current energizes the magnetic coil to pull the release mechanism almost instantaneously, driving the arc into the quenching chamber to clear the fault before busbars or conductors suffer heavy damage.
Front TRIP Test Button: Right on the front face below the operating handle, a red TRIP button lets technicians manually verify trip linkage release during panel commissioning without injecting high test current.
Rated Specifications From the Nameplate
When checking technical schedules for low-voltage assemblies, the nameplate ratings define the breaker's switching and insulation limits:
Parameter
Rated Specification
Practical Engineering Meaning
Poles & Rated Current (I_n)
3 Pole (3P) / 160A
Fits three-phase low-voltage feeder and main distribution circuits
Rated Operational Voltage (U_e)
AC 240V / 400V / 690V
Covers standard 400V commercial/industrial grids and 690V heavy circuits
Ultimate Breaking Capacity (I_{cu})
100kA (240V) / 85kA (400V) / 20kA (690V)
Maximum prospective fault current the breaker is rated to clear
Service Breaking Capacity (I_{cs})
80kA (240V) / 50kA (400V) / 10kA (690V)
Indicates fault interruption capability while remaining fit for continued service
Rated Insulation Voltage (U_i)
AC 690V
Sets the voltage reference for internal phase and earth insulation clearances
Rated Impulse Withstand (U_{imp})
6kV
Withstands transient switching and lightning-induced voltage spikes
Utilization Category & Temp
Cat A / 50Hz / +40°C
Suited to general-purpose non-selective protection with ratings calibrated at +40°C
Standards & Marks
IEC 60947-2 / GB 14048.2 / CCC
Aligns with international low-voltage switchgear testing standards
Selection and Installation Notes to Avoid Field Mistakes
Follow LINE and LOAD Markings: The molded housing clearly marks LINE at the top supply side and LOAD at the bottom load side. Wire the supply feed to the LINE terminals as intended so arc extinguishing and trip mechanics perform properly during high-fault interruption.
Fit Phase Barriers on Heavy Terminations: When terminating wide copper busbars or heavy cable lugs, install insulating phase barriers between terminals to keep creepage and clearance paths safe inside crowded enclosures.
Account for Ambient Enclosure Heat: Thermal trip calibration references a +40°C ambient baseline. If you mount the breaker inside a sun-exposed outdoor box or poorly ventilated cabinet exceeding +40°C, review temperature derating or cabinet ventilation early in panel design.
Factory Checks, OEM Customization, and Dispatch
Dongfa Intelligent manufactures this 160A 3 pole thermal magnetic molded case circuit breaker with factory routine checks covering thermal trip timing, magnetic trip response, dielectric withstand, and mechanical switching cycles before shipping.
OEM Branding & Neutral Option: We support neutral faceplates or custom customer silk-screen markings (brand logo, part codes, and ratings) for regional distributors and OEM panel builders.
Sample & Bulk Packaging: Buyers can request sample units for local testing before placing volume orders, with each breaker packed in an individual box and outer cartons suited to sea freight.
Technical Specifications
Thermal-Magnetic Molded Case Circuit Breaker
125
160
250
400
630
800
1250
2000
Frame Rated Current In (A)
10A-125A
16A-160A
100A-250A
250A-400A
500A-630A
800A-800A
800A-1250A
1000A-2000A
Poles
1P,2P,3P,4P
2P,3P,4P
3P,4P
3P,4P
Rated Insulation Voltage Ui (V)
1000V
Rated Impulse Withstand Voltage Uimp (kV)
8Kv
Rated Operational Voltage Ue (V), AC
230V;400V;690V
Breaking Capacity Code
C
S
M
H
C
S
M
H
C
S
M
H
S
M
H
M
H
M
H
S
M
H
M
H
Rated Service Short-Circuit Breaking Capacity Ics (kA)
Are you a factory or trading company, and can we order samples first?
We are a direct manufacturer with 14 years of low-voltage and medium-voltage electrical manufacturing experience. Sample orders are available so your team can test fitment and performance before committing to bulk quantities.
Can this 160A breaker take shunt trip, undervoltage, or auxiliary contacts?
Yes. Internal accessory slots support common add-ons such as auxiliary contacts, shunt trips, undervoltage releases, or rotary handles depending on your control circuit requirements.
What is the typical lead time for bulk and OEM orders?
Standard 160A configurations typically ship in 5–7 working days when stock components are ready, while custom OEM printing or accessory assemblies generally take 10–15 working days.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy