Dongfa Intelligent supplies 250A 4 pole residual current MCCBs for panel builders needing overload, short-circuit, and earth leakage protection. Rated 250A with 35/25kA at 400V and adjustable mA/time dials, it fits distribution panels. Request a quote for pricing and specs.
Combining Circuit Protection and Earth Leakage Detection in 4-Pole Panels
In four-wire distribution feeders supplying outdoor equipment, damp workshops, wet processing lines, or portable machinery, phase-to-earth insulation faults often develop gradually before becoming full phase-to-phase short circuits. A standard thermal-magnetic breaker alone trips on overloads and short circuits, whereas adding residual current monitoring helps detect ground leakage currents and open the circuit before prolonged leakage damages equipment or creates shock hazards.
Dongfa Intelligent supplies this 250A 4 pole residual current MCCB to combine thermal-magnetic overcurrent protection with electronic residual current protection in a single molded case frame. Built to IEC 60947-2 and GB/T 14048.2 standards, it suits commercial and industrial switchboards where ground-fault protection is required alongside overload and short-circuit clearing.
Faceplate Controls, ELCB Dials, and 4-Pole Layout Details
A close look at the front faceplate shows how the breaker separates standard overcurrent switching on the left from residual current settings on the right:
4-Pole Configuration With Marked Neutral (N): The physical unit has four poles with the neutral pole clearly marked N on the upper right, LINE at the top supply end, and LOAD at the bottom load end.
Adjustable Residual Current and Time Dials: Under the ELCB section on the right faceplate, blue slotted rotary dials allow setting rated residual operating current (IΔn in mA, with scale markings showing 50, 100, 300, and 800 mA on the faceplate, while the series datasheet lists 50, 100, 200, 300, 500, 800, and 1000 mA with any four adjustable) and maximum non-actuating/operating time (Δt in seconds, with markings at 0.1, 0.45, 1.0, and 2.0 s alongside Δt(s) 0.05/0.2/0.5/1.0).
Yellow Leakage Test Button and Red TRIP Button: A yellow test button sits in the ELCB section to verify residual current trip operation, while a red TRIP button sits on the lower left for mechanical release checks.
Parameter
Nameplate / Spec Value
Practical Engineering Meaning
Frame & Rated Current (I_n)
250A (series spans 125A–1250A frames)
Fits 250A four-wire distribution feeders and sub-panels
Poles & Neutral Marking
4P with N pole marked
Switches three phases and neutral together for four-wire circuits
Rated Operational Voltage (U_e)
AC 400V
Matches standard three-phase four-wire 400V AC distribution networks
Breaking Capacity (I_{cu}/I_{cs})
35kA / 25kA
Defines ultimate short-circuit breaking and service continuity at 400V
Insulation / Impulse (U_i / U_{imp})
AC 1000V / 8kV
Sets dielectric insulation reference and impulse withstand level
Residual Current Type & Release
AC type / Electronic residual release
Monitors AC residual fault current through an electronic sensing circuit
Adjustable IΔn & Time Settings
Adjustable mA & time delay dials (ELCB)
Enables tuning sensitivity and time delay to match system coordination
Utilization Category & Ambient
Cat A / 50Hz / +40°C
Calibrated at +40°C ambient for general non-selective protection
Field Commissioning Tips, Factory Testing, and OEM Support
When commissioning a 250A 4 pole residual current MCCB on site, two practical steps save troubleshooting time later. First, use the yellow leakage test button periodically after installation to verify that the electronic residual trip mechanism releases properly. Second, keep phase and neutral conductors routed cleanly through the breaker as intended so normal load current sums to zero without false leakage signals, and confirm that your selected IΔn sensitivity and time delay setting align with upstream and downstream selectivity.
Across the broader residual current MCCB range, frame sizes span from 125A up to 1250A with 2P/3P/4P options depending on frame. Drawing on 14 years of low- and medium-voltage electrical manufacturing experience in Yueqing, Dongfa Intelligent tests units under ISO 9001 controls and IEC 60947-2 / GB/T 14048.2 standards—verifying mechanical switching, insulation integrity, overcurrent release, and residual trip response before dispatch, with sample units and custom OEM silk-screen markings available.
Technical Specifications
Molded Case Circuit Breaker (with Residual Current Protection)
50, 100, 200, 300, 500, 800, 1000 (any four adjustable)
50, 100, 200, 300, 500, 800, 1000 (any four adjustable)
50, 100, 200, 300, 500, 800, 1000 (any four adjustable)
IΔm (kA)
16.25kA
16.25kA
16.25kA
16.25kA
16.25kA
16.25kA
12.5kA
12.5kA
12.5kA
12.5kA
–
–
12.5kA
12.5kA
–
–
12.5kA
12.5kA
–
16.25kA
Residual Current Type
AC type
AC type
AC type
AC type
AC type
AC type
AC type
Selectivity Category
Class A
Class A
Class A
Class A
Class A
Class A
Class A
Overcurrent Release Type
Thermomagnetic
Thermomagnetic
Thermomagnetic
Thermomagnetic
Thermomagnetic
Thermomagnetic
Thermomagnetic
Residual Current Release Type
Electronic
Electronic
Poles (Dimensions)
3P
4P
3P
4P
3P
4P
2P
3P
4P
2P
3P
4P
3P
4P
3P
4P
Width W (mm)
140
184
210
280
210
280
50
75
100
60
90
120
105
140
140
184
Length L (mm)
257
257
275.5
275.5
275.5
275.5
130
130
130
155
155
155
165
165
257
257
Height – Cover (mm)
103
103
103
103
103
103
68
68
68
68
68
68
68
68
103
103
Height – Handle (mm)
152
152
152
152
152
152
94.5
94.5
94.5
94
94
94
96
96
152
152
Buyer Feedback and Common Questions
"We used Dongfa Intelligent's 250A 4 pole residual current MCCBs on a commercial distribution upgrade with damp utility rooms. Having clear N pole markings, front ELCB dials, and a yellow test button made panel assembly and site checks straightforward, and testing a sample first went smoothly."
— Daniel K., Engineering Manager at a Middle Eastern Switchgear Assembly Contractor
How do you test the residual current function after installing the breaker?
Press the yellow ELCB test button on the right side of the front faceplate during commissioning or routine maintenance checks to confirm the leakage trip mechanism actuates as expected.
Can we order 1 unit at 250A first for sample and panel testing?
Yes. Sample and small-batch orders are available so your team can check the 4-pole dimensions, dial settings, and panel fitment before placing bulk orders.
Can you print our own brand logo or model markings on the front plate?
Yes. Neutral faceplates or custom customer silk-screen markings can be provided, with MOQs and lead times confirmed according to your order requirements.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy