Dongfa Intelligent supplies 400A electronic molded case circuit breakers for switchgear builders needing selective protection. Rated 400A with 50/50kA at 400V, 10kA/1s Icw, and multi-dial tuning, it fits distribution panels. Request a quote for pricing and specs.
Selective Protection and Multi-Parameter Tuning in Medium-Capacity Panels
In switchboards where downstream feeders must trip before upstream main breakers open, fixed thermal-magnetic trip curves often leave too little room for time and current selectivity. Electronic trip units give panel engineers finer control over pickup thresholds, short-time delay, and fault discrimination across commercial and industrial distribution boards.
Dongfa Intelligent supplies this 400A electronic molded case circuit breaker for switchgear assemblies requiring rotary dial settings and Cat B selectivity support. Built to IEC 60947-2 and GB/T 14048.2 standards, it brings electronic overcurrent sensing together with status indicators on the front face.
Reading the Front Controls, Indicators, and Nameplate Ratings
Zooming in on the front face of this 400A unit highlights several hardware details that distinguish it from standard thermal-magnetic breakers:
Six Rotary Adjustment Dials: Along the lower front strip sit six blue slotted rotary dials labeled across current and time parameters (Ir(A), tr(s), Isd(×Ir), tsd(s), Ii(×Ir), and Ig(×In) / ground fault dial markings), allowing structured tuning of long-time, short-time, instantaneous, and ground settings.
Three Front Status LEDs and Red TRIP Button: On the lower-right panel above the dial strip are three indicator lights labeled Error, Alarm, and MCU, while a red TRIP button sits on the lower left for manual mechanical trip verification.
Nameplate Ratings and Cat B Designation: The nameplate shows In 400A with IR 200-400A adjustable range, Ue AC 400V, Icu/Ics 50/50kA, Icw 10kA/1s, Ui AC 1000V, Uimp 8kV, Cat B, and 50Hz, with LINE at the top and LOAD at the bottom.
Parameter
Nameplate / Spec Value
Practical Engineering Meaning
Rated Current & Range (I_n / I_R)
400A (IR 200-400A; series spans 160A–2000A frames)
Fits 400A feeder and incomer bays with adjustable current range
Rated Operational Voltage (U_e)
AC 400V (series rated AC 400V, AC 690V)
Matches standard 400V AC industrial and commercial distribution panels
Breaking Capacity (I_{cu}/I_{cs})
50kA / 50kA at AC 400V
Full Ics = 100% Icu rating supports service continuity after fault clearing
Short-Time Withstand (I_{cw})
10kA/1s
Supports short-time delay selectivity by holding 10kA for 1 second
Insulation / Impulse (U_i / U_{imp})
AC 1000V / 8kV
Sets dielectric insulation reference and impulse withstand margins
Utilization Category & Release
Cat B / Electronic overcurrent release
Designed for selective protection with intentional short-time delay
Frequency
50Hz on nameplate (50/60Hz in series spec)
Aligns with grid frequency requirements across target projects
Commissioning Practices, Manufacturing Controls, and Buyer Support
When putting a 400A electronic MCCB into service, verify the Error, Alarm, and MCU status indicators during power-up, confirm that each rotary dial is seated cleanly in its intended notch with a suitable flat screwdriver, and check selectivity time settings against downstream breakers so fault clearance follows your intended hierarchy.
Across the electronic MCCB family, frame ratings span from 160A up to 2000A across S, M, and H breaking codes in 3P and 4P configurations. With 14 years of low- and medium-voltage electrical manufacturing experience in Yueqing, Dongfa Intelligent tests every production batch under ISO 9001 controls and IEC 60947-2 / GB/T 14048.2 standards—checking mechanical operation, insulation and dielectric strength, and trip unit response prior to shipment, with sample orders and custom OEM silk-screen markings available.
"We used Dongfa Intelligent's 400A electronic MCCBs on a commercial distribution board where time discrimination mattered. Having 50/50kA breaking at 400V, 10kA/1s withstand, and clear front indicators and dials made panel setup smooth after testing a sample first."
— Kevin H., Lead Switchgear Engineer at a Commercial Power Distribution Integrator
What do the Error, Alarm, and MCU indicators on the front face represent?
They provide visual status feedback on the electronic control unit (MCU), alarm states (Alarm), and fault/error conditions (Error) on the front panel during operation and commissioning.
Can we order 1 unit at 400A first for sample and panel testing?
Yes. Sample and small-batch orders are available so your engineers can verify frame fitment, dial adjustments, and selectivity setup before bulk ordering.
Can you apply our own brand name or model markings on the faceplate?
Yes. Neutral faceplates or custom customer silk-screen markings can be arranged, with MOQs and lead times confirmed per order configuration.