Dongfa Intelligent supplies 1250A electronic LCD molded case circuit breakers for switchgear builders needing clear status visibility and trip tuning. Rated 1250A with 65/50kA at 400V, 20kA/1s Icw, and an LCD display, it fits main panels. Request a quote for pricing and specs.
    1250A Electronic LCD Molded Case Circuit Breaker

    Why Main 1250A Panels Often Call for Electronic LCD Breakers

    On large plant switchboards, commercial substation incomers, and high-current feeder bays, a 1250A breaker handles heavy continuous loads where unplanned outages disrupt whole sections. Standard mechanical or fixed-dial units protect circuits reliably, yet maintenance teams often want clearer screen readouts, status indicators, and parameter visibility when checking load conditions or reviewing a trip event.

    Dongfa Intelligent supplies this 1250A electronic LCD molded case circuit breaker to pair electronic trip protection with front-panel LCD visibility in a 1250A frame. Built to GB/T 14048.2, it helps panel builders and facility engineers monitor status and tune settings across heavy low-voltage distribution boards.

    Reading the Front Face, LCD Area, and Nameplate Ratings

    A close look at the front panel and nameplate markings shows how this 1250A unit organizes its display, indicators, and ratings:

    Lower-Right LCD Display and Three Status LEDs: An LCD screen sits on the lower right below the rating block, paired with three status indicators marked for power, alarm, and communication status so technicians can check operating states at a glance.

    Control Buttons, Terminal Strip, and TRIP Button: Below the LCD area sit pushbuttons and a multi-pin terminal strip for control/communication wiring, while a red TRIP button on the lower left allows mechanical trip checks and LINE and LOAD mark the top and bottom terminations.

    Nameplate Voltage, Breaking, and Withstand Ratings: The nameplate shows In 1250A, Ue AC 400V / AC 690V, breaking capacity Icu/Ics at 65/50kA (AC 400V) and 30/20kA (AC 690V), short-time withstand Icw 20kA/1s, insulation Ui AC 1000V, impulse withstand Uimp 8kV, Cat A, and 50Hz.

    Parameter Nameplate / Spec Value Practical Engineering Meaning
    Rated Current (I_n) 1250A (0.4–1.0In adjustable range in series spec) Fits 1250A main incomer and heavy distribution feeder bays
    Rated Operational Voltage (U_e) AC 400V / AC 690V on nameplate (AC400V in spec table) Covers 400V and 690V AC low-voltage power distribution networks
    Breaking Capacity (I_{cu}/I_{cs}) 65/50kA at AC 400V; 30/20kA at AC 690V Defines short-circuit breaking limits and post-fault service continuity
    Short-Time Withstand (I_{cw}) 20kA/1s Holds 20kA for 1 second to support time-graded coordination
    Insulation / Impulse (U_i / U_{imp}) AC 1000V / 8kV Sets dielectric insulation reference and impulse withstand margin
    Display & Status Indicators LCD screen + power, alarm, and communication indicators + buttons Supports local display viewing, status checks, and parameter adjustments
    Standard GB/T 14048.2 Built to national low-voltage switchgear and controlgear standards

    Enclosure Layout Checks, Frame Series, and Shop-Floor Testing

    When mounting a 1250A electronic LCD MCCB inside a switchboard, align door cutouts or viewing windows early so the LCD screen and front buttons remain accessible during inspection, and leave clean busbar and bottom terminal clearance around LINE and LOAD.

    Across the electronic LCD MCCB lineup, frame options span from 250A to 1250A across 3P and 4P dimensions (such as 210mm width, 275.5mm length, 103mm cover height, and 152mm handle height on 3P, and 280mm width on 4P). With 14 years of low- and medium-voltage electrical manufacturing experience in Yueqing, Dongfa Intelligent verifies every production batch under ISO 9001 controls and GB/T 14048.2—checking main circuit continuity, switching mechanics, LCD and indicator operation, and dielectric withstand before shipping, with sample orders and custom OEM silk-screen markings available.

    Technical Specifications

    Molded Case Circuit Breaker STM6EY-250 STM6EY-400 STM6EY-630 STM6EY-800 STM6EY-1250
    Breaking Capacity Code M H M H M H M H M H
    Frame Rated Current In (A) 125A (0.4–1.0In); 250A (0.4–1.0In) 400A (0.4–1.0In) 630A (0.4–1.0In) 630A (0.4–1.0In); 800A (0.4–1.0In) 1000A (0.4–1.0In); 1250A (0.4–1.0In)
    Poles 3P; 4P 3P; 4P 3P; 4P 3P; 4P 3P; 4P
    Rated Working Voltage Ue, AC AC400V AC400V AC400V AC400V AC400V
    Rated Insulation Voltage Ui (V) 1000V 1000V 1000V 1000V 1000V
    Rated Impulse Withstand Voltage Uimp (kV) 8kV 8kV 8kV 8kV 8kV
    Ics @ AC400V (kA) 35kA 65kA 50kA 70kA 50kA 70kA 50kA 65kA 50kA 65kA
    Icu @ AC400V (kA) 50kA 65kA 50kA 70kA 50kA 70kA 50kA 85kA 50kA 85kA
    Rated Short-Time Withstand Current Icw – – 10kA/1s 10kA/1s 10kA/1s 10kA/1s 20kA/1s 20kA/1s 20kA/1s 20kA/1s
    Selectivity Category Class B Class B Class B Class B Class B
    Overcurrent Release Type Electronic Electronic Electronic Electronic Electronic
    Poles (Dimensions) 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P
    Width W (mm) 105 140 140 184 210 280 210 280 210 280
    Length L (mm) 165 165 257 257 275.5 275.5 275.5 275.5 275.5 275.5
    Height – Cover (mm) 88 88 103 103 103 103 103 103 103 103
    Height – Handle (mm) 116 116 152 152 152 152 152 152 152 152

    Customer Feedback and Common Questions

    "We used Dongfa Intelligent's 1250A electronic LCD MCCBs on a plant main distribution board upgrade. Having the LCD readout and status indicators right on the front made checks straightforward alongside 65/50kA breaking at 400V and 20kA/1s withstand, and starting with a sample unit kept rollout smooth."

    — Tariq A., Technical Lead at a Middle Eastern Industrial Switchgear Builder

    What do the three indicator lights below the LCD screen show?

    The front panel marks power, alarm, and communication status indicators so operators can quickly check supply status, alarm alerts, and communication state.

    Can we order 1 unit at 1250A first for sample and cabinet testing?

    Yes. Sample and small-batch orders are available so your engineers can verify 1250A frame fitment, LCD display operation, and panel alignment before bulk purchasing.

    Can you print our brand name or custom markings on the front face?

    Yes. Neutral faceplates or custom customer silk-screen markings can be provided, with MOQs and lead times confirmed per order configuration.

    Send Inquiry
    Contact Info
    Contact Dongfa Intelligent for electrical products. We welcome your inquiry and will provide product details, pricing and technical support.
    X
    We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
    RejectAccept