Follow Us:

Products

Vacuum Circuit Breakers Manufacturer for Reliable Power Distribution

View as  
 
12kV Indoor Embedded Pole Vacuum Circuit Breaker

12kV Indoor Embedded Pole Vacuum Circuit Breaker

Dongfa Intelligent provides project sourcing and technical selection of the 12kV Indoor Embedded Pole Vacuum Circuit Breaker, designed for compact and reliable indoor medium-voltage power distribution systems. The ZN63(VS1)-12 integrates the vacuum interrupter into an embedded pole structure to provide stable insulation and a more compact switching assembly. With rated current options from 630A to 4000A, short-circuit breaking capacity up to 40kA, and flexible switchgear integration, it is suitable for utilities, power plants, mining and industrial applications. Model: ZN63(VS1)-12 Parameters: 12kV |630A–4000A |20/25/31.5/40kA
12kV Indoor Permanent Magnet Vacuum Circuit Breaker

12kV Indoor Permanent Magnet Vacuum Circuit Breaker

Dongfa Intelligent supports sourcing and technical selection of the 12kV Indoor Permanent Magnet Vacuum Circuit Breaker for indoor medium-voltage power distribution systems. The ZN63A(VS1)-12 uses a bistable permanent magnet operating mechanism that reduces mechanical components and shortens the transmission chain compared with conventional spring mechanisms. With up to 20,000 mechanical operations, short-circuit breaking capacity up to 40kA, and multiple rated-current configurations, it is designed for utilities, power plants, mining and industrial applications. Model: ZN63A(VS1)-12 Key Specifications: 12kV | 630A–2500A | 20 / 25 / 31.5 / 40kA
12kV Indoor Vacuum Circuit Breaker

12kV Indoor Vacuum Circuit Breaker

Dongfa Intelligent supports sourcing, technical selection and project procurement of 12kV Indoor Vacuum Circuit Breaker solutions. The ZN63(VS1)-12 is designed for indoor medium-voltage power distribution, with rated current from 630A to 4000A and short-circuit breaking capacity up to 40kA. Fixed and withdrawable configurations are available for different switchgear layouts, while 10,000-operation mechanical life supports long-term switching reliability. Suitable for utilities, power plants, mining and industrial applications. Model: ZN63(VS1)-12 Breaking Capacity: 20 / 25 / 31.5 / 40kA
Dongfa Intelligent is a professional Vacuum Circuit Breakers manufacturer and supplier in China. We offer Vacuum Circuit Breakers and related electrical products for power distribution applications with technical support.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept